Safe shopping with solar experts
Fast Shipping
Top choice renowned brands
Customer service:
+49 (0) 8721 91994-00

The Multiplus-II 12/3000/120-32 is a high-end device combination from victron Energy (mpn pmp122305010) that combines classic Multiplus components with an external current sensor and integrated anti-islanding function. This extends the PowerControl and Powerassist functions to 50 a and the potential range of use to ESS applications. The inverter module delivers a whopping 3000 w at non-linear load, or 2400 w at linear continuous load. the 12 v battery charger is also very well proportioned, with 120 a charging power, and is complemented by a 32 a transfer switch that allows lightning-fast switching between aC connections.

important features of the Multiplus-II 12/3000/120-32

  • PowerControl and Powerassist -increase in mains or generator output
  • built-in anti-islanding function and connection possibility for external current sensor (optional)
  • can be used as a backup device in grid-connected systems for power supply in case of grid failures
  • can be used in various applications
  • best suited for professional seafaring, yachts, vehicles and land-based, off-grid applications
  • vE.Bus interface for parallel and three-phase operation, remote monitoring and system integration
  • virtually unlimited power through parallel and three-phase operation
  • can be configured on-site or remotely using vEConfigure software*

Technical features

  • 3000 w power at non-linear load 2400 w continuous load and 5500 w peak power
  • for 12 v battery voltage, 32 a transfer switch and 120 a battery charger
  • output voltage: 230 vaC, frequency: 50 Hz
  • max. efficiency is 95%, protection class IP22

Always enough power thanks to PowerControl and Powerassist

a maximum mains or generator current can be set on the Multiplus-II 12/3000/120-32. The MultiPlus-II then takes into account other connected AC consumers and only uses the current that is "left over" to charge the battery. This prevents the generator or mains connection from being overloaded (PowerControl function). The Powerassist function adds a new dimension to the PowerControl principle. Load peaks often only occur for a limited period of time. In such a case, the MultiPlus-II immediately compensates for insufficient generator, shore power or mains power with energy from the battery. if the load is reduced, i.e. if consumers are switched off, the energy that is then available again in sufficient quantities can be used to charge the batteries.

Solar power: alternating current even in the event of a power failure

The device can be used with both non-grid-connected and grid-connected pv systems, as well as with other alternative energy systems. It can be used with both solar charge controllers and grid-connected inverters.

Maximum flexibility thanks to two AC outputs

The main output ensures uninterrupted operation. In case of grid failure or interruption of shore/generator power, the MultiPlus-II takes over the supply of the connected loads. Switching occurs so quickly (in less than 20 milliseconds) that uninterrupted operation of computers and other electronic equipment is guaranteed. The second output supplies power only when AC power is available at the input of the MultiPlus-II. consumers that must not discharge the battery, such as a water heater, can be connected to this output.

many possibilities for system expansion

Settings can be changed in minutes using the vEConfigure software (which requires a computer or laptop and an MK3 USB interface).several monitoring and control options are available: Color Control gx, venus gx, Octo gx, CaNvu gx, laptop, computer, Bluetooth (with the optional vE.Bus Smart Dongle), battery monitor, Digital Multi control panel.

Remote configuration and monitoring

Install a Color Control gx or other gx products to connect to the Internet. Operating data can be stored and viewed free of charge on our vRM (victron Remote Management) website. If systems are connected to the Internet, they can be accessed remotely and settings can be changed.

Scope of delivery:

1x victron pmp122305010 Multiplus-II 12/3000/120-32a
1x user manual

Victron_ESS_Installationshandbuch.pdf Download
Victron_MultiPlus-II_CE.pdf Download
Victron_MultiPlus-II-12-3000-230V_Dimensions.pdf Download
Victron_MultiPlus-II_Certificate-ESS-NRS-097.pdf Download
Victron_ESS_Installation-Manual.pdf Download
Victron_MultiPlus-II-3kVa-15kVa-230V_Datasheet.pdf Download
Victron_MultiPlus-II-230V_Handbuch.pdf Download
Victron_MultiPlus-II-230V_Manual.pdf Download
Victron_Automatic-Generator.pdf Download
Victron_MultiPlus-II-3kVa-15kVa-230V_Datenblatt.pdf Download
Charging voltage: 28,8V
Continuous output: 2400W
Input voltage: 9,5 - 17V
Manufacturer: Victron Energy
Protection type: IP22
Rated output voltage: 230V AC / alternating current
Weight: 19kg
ean: 8719076048916
mpn: PMP242305010

Manufactuerer Information

Victron Energy

Victron Energy B.V.
De Paal 35
1351 JG Almere
Netherlands

Mail: sales@victronenergy.com

Tel.: +31 365359700

offgridtec.com Reviews with ekomi.de