Growatt spa 7000tl3 bh-up 7kW 3-phase grid inverter
Shipped in 1-3 days
€1,694.12*
€1,423.63**
The spa 7000tl3 bh-up from Growatt is a 3-phase grid inverter that provides a state-of-the-art solution for your solar projects. With three programmable operating modes, a VPP interface and a wide battery voltage range of 100-550v, it offers efficiency and flexibility. In addition, it supports retrofits and new systems and ensures compatibility with high-voltage batteries.
about the spa 7000tl3 bh-up inverter
- 100% three-phase unbalanced output
- Intelligent power control at phase level
- Intelligent load control via dry contact
- Wide battery voltage range 100-550 V
- UPS function, 10ms transfer
- VPP interface
- Programmable operating modes
- Display via led and lcd
- Supports lithium and lead-acid batteries
- Easy installation
Intelligent load management
The inverter's integrated smart load control enables precise and efficient control of energy consumption. By using a potential-free contact, electrical loads can be controlled intelligently and prioritized. This function enables automatic detection of energy requirements and optimum use of the available energy. Smart load management ensures optimum distribution of energy and thus contributes to efficient use. With intelligent load control via the dry contact, the inverter is able to optimize the energy flow and ensure efficient operation of your Solarasystem.
Growatt monitoring platform
By using the optional accessories of the Shine series, you can use the Growatt monitoring platform. This platform is available as a smartphone app for iOS and Android as well as a web version. The Shine accessories must be purchased separately, but use of the platform is free of charge. you can configure and monitor all your Growatt products via Shine, and it also allows you to view self-consumption and track trends.
The following Shine options are compatible with the spa series:
- ShineWiFi-X
- ShineLink-X
- Shine4G-X
- ShineMaster
Operating modes - Configurable according to system requirements
Online mode
Users can set a suitable priority mode in online mode according to the request while the spa is working. If the lcd and button settings are used, only one time period can be set. However, if the website settings are used, up to three time periods can be set for the priority mode
- Load First: With an inverter in the spa system, the energy from the inverter is optimized for the load and then the battery is charged. surplus energy is exported to the grid. Without Inverter or if the energy is low, the battery discharges first for the load and the grid supplies the energy if the battery capacity is insufficient.
- Battery First: When the spa series operates in this mode, the battery is charged first. This is suitable for periods of low power consumption. The switch-on and switch-off times of the mode and the end time of the battery charge level must be set. It is also possible to set a power that is lower than the maximum output power of the battery. With an inverter in the spa system, the energy from the inverter is first used for the battery, then for the load. The grid supplies the energy if the power of the inverter is not sufficient. Without Inverter or if its power is too low, the battery and the load are supplied by the mains.
- Grid First: If the spa series is operating in grid-first mode, the energy is fed into the grid first. Time periods can be set when the power consumption is too high. The switch-on and switch-off times of the mode and the end time of the battery charge level must be set here. A power can be set that is lower than the maximum output power of the battery. With an inverter in the spa system, the battery discharges to the load. If the sum of inverter power and battery power is greater than the load, excess energy flows into the grid. Without Inverter or if its energy is too low, the battery discharges to the load and excess energy flows into the grid.
Backup mode:
If the grid fails, the system switches to backup mode and AC power is output via the eps LOAD port using all the energy from the battery. Note that the maximum output power of the spa in this mode is 10,000w and the load connected to the eps LOAD port should be less than 10,000w. Note: You can only set a time period for "Battery First" and "Grid First" on the lcd. If you want to set more than this, you have to do so via the shineserver.
Error mode:
The spa`s intelligent control system continuously monitors and adjusts the status of the system. If the inverter detects unexpected events such as system error or machine error, the lcd display will show the error information and the led light will light up in error mode.
Programming mode:
Programming mode indicates that the spa system is being updated. The power supply should not be interrupted during the process. The inverter is automatically logged out when the update is complete and switches to another mode.
verification mode:
Before the spa operates in normal mode, it will switch to self-check mode. If everything is OK then, the system will switch to normal mode. Otherwise, the error mode will respond.
Standby mode:
If the system has no errors but the conditions are not met, the spa remains in standby mode.
Technical data
- AC rated power: 7000W
- AC nominal voltage range: 230/400v (310-476V)
- Frequency range: 50/60Hz, ±5Hz
- Max. Output current: 10.6A
- Battery voltage range: 100-550v
- Max. Charging and discharging current: 25A
- IP protection class: IP65
- Manufacturer's warranty: 10 years
- Operating temperature range: -25°C - +60°C
- Maximum efficiency of 98.2%
- Dimensions: 505 x 453 x 198 mm
- Weight: 28 kg
Scope of delivery
1x Growatt spa 7000tl3 bh-up grid inverter
Note on Growatt inverters in use with batteries
Please note that the MIN, MOD, SPH and SPA series inverters may only be operated with original Growatt batteries. All Growatt inverters sold in Europe are not compatible with lead-acid batteries. Their use can lead to malfunctions or damage to the devices. Furthermore, no warranty claims can be made.